For heat insulation and the improvement of energy efficiency of roofs and floors we offer commercial customers EPS (expanded polystyrene) and mineral rock wool. These products are German products and have all the necessary certification reports.
Benefit from our lean supply chain: we supply EPS and mineral rock wool directly from the production plant to you or the desired construction site – without entrepot – and thereby without extra costs for you! By doing so, we can always offer fair and attractive prices.
Our product range contains materials of very different quality requirements:
EPS (expanded polystyrene)
Building material category DIN 4102-1, B1
Scope of application according to DIN 4108 – part 10
Chemically and biologically neutral, – 100 % free of CFC, HCFC, HFC
Screed insulation
DEO
(Internal insulation of the slab or the bottom slab below
the screed without soundproofing requirements)
≥ 100 kPa = 100 kN/m² = 10 t/m² = 0,10 N/mm² – heat conductance group 040
≥ 100 kPa = 100 kN/m² = 10 t/m² = 0,10 N/mm² – heat conductance group 035
≥ 150 kPa = 150 kN/m² = 15 t/m² = 0,15 N/mm² – heat conductance group 035
Footfall sound
(Internal insulation of the slab or the bottom slab below the screed with
soundproofing requirements)
4,0 kpa DES sm WLG 045
5,0 kpa DES sg WLG 040
Flat roof insulation
DAA dm
(Exterior insulation of roof and ceiling or sealing, medium compression strength)
≥ 100 kPa = 100 kN/m² = 10 t/m² = 0,10 N/mm² – heat conductance group 040
≥ 100 kPa = 100 kN/m² = 10 t/m² = 0,10 N/mm² – heat conductance group 035
DAA dh
(Exterior insulation of roof and ceiling below the sealing, high compression strength)
≥ 150 kPa = 150 kN/m² = 15 t/m² = 0,15 N/mm² – heat conductance group 035
≥ 200 kPa = 200 kN/m² = 20 t/m² = 0,20 N/mm² – heat conductance group 035
We offer flat roof insulation panels with raw glass fleece lamination upon request.
Pitched roof insulation
(wedge-shaped hard-foam boards with a gradient of at least 2% to the heat insulation of flat roofs)
Manufacturing after submission of drawing made by customer and the confirmed bill of materials
DAA dm
(Exterior insulation of roof and ceiling or sealing, medium compression strength)
≥ 100 kPa = 100 kN/m² = 10 t/m² = 0,10 N/mm² – heat conductance group 040
≥ 100 kPa = 100 kN/m² = 10 t/m² = 0,10 N/mm² – heat conductance group 035
DAA dh
(Exterior insulation of roof and ceiling below the sealing, high compression strength)
≥ 150 kPa = 150 kN/m² = 15 t/m² = 0,15 N/mm² – heat conductance group 035
≥ 200 kPa = 200 kN/m² = 20 t/m² = 0,20 N/mm² – heat conductance group 035
Mineral wool / rock wool
Scope of application DAA according to DIN 4108-10
Fire class A1
For heat and soundproofing insulation of non-ventilated flat roof and industrial roof tops
Flat roof insulating board
Compression strength ≥ 60 kPa = 60 kN/m² = 6 t/m² = 0,06 N/mm² – =
Compression strength ≥ 70 kPa = 70 kN/m² = 7 t/m² = 0,07 N/mm² –
Compression strength ≥ 80 kPa = 80 kN/m² = 8 t/m² = 0,08 N/mm² –
Incline insulation board
(wedge-shaped mineral wool boards with an incline of at least 2% to the heat insulation of flat roofs)
Manufacturing after submission of drawing made by customer and the confirmed bill of materials
Compression strength ≥ 60 kPa = 60 kN/m² = 6 t/m² = 0,06 N/mm² –